Add to Cart
Professional 0 - 50J / cm2 RF beauty machine with 10.4 inches touch color screen
Introduction of Operating System
1. Initial display on turning on the machine (show as picture one):
2. Menu
A. touch Enter on screen, then enter into picture two:
B. touch Treatment Area on screen then enters into picture three to choose the parts you want to treat
C. Adjust the RF level,
The machine make the Bi polar as default, adjust the anergy and cooling and READY, then the machine start to Bi-polar work.
Suggest the energy start adjust from 60 on Bi-polar
D. The max energy show is 200j, the adjust unit is 4j.
1. Treatment Theory
RF beauty equipment is the high-tech beauty equipment, great safety and no wound.
The collagen is the main skin tissue. However, the collagen and elastin will reduce and lack because of sun oxidation and air pollution as the time flies. As the sustainment of skin, flexibility fiber and collagen fiber would gradually lose its elasticity and tensility. Sagging skin or other visible signs of aging will appear.
The RF equipment offers a best cooling effect on epidermis, and takes advantage of the heat energy released from the probe, directly transfer to deep skin tissue. The heat will stimulate the friction between cation and anion inside the cell, accelerates the thermal motion on dermis. That accelerates blood circulation under dermis and subcutaneous tissue, which lets the fiber structure shrink instantaneously, and stimulates the renewal of collagen. In response, smooth and tight kin, renewed facial contours can be expected.
2. Application:
1. Facial skin tightening
2. Fine wrinkle removal
3. Neck skin tightening
4. Improve the conditions of sagging skin
5. Forehead wrinkle removal
6. Breast lifting
7. Renew back contours
8. Renew belly contours
9. Renew buttocks and legs contours
10. Hand care
1. Collagen renewal: the RF energy could be reached the deep layers of skin, stimulating the renewal of the collagen tissue. In response, the best result of skin tightening, renewed facial contours can be expected.
2. Big color touch screen, 10.4 inch, simple operation.
3. Instantaneous skin shrinking: when the temperature of collagen up to 45oc-60oc, the collagen will shrink instantaneously. Therefore, one treatment could let u feel the best result.
4. Long renewal effect: after half year’s treatment, the renewal of collagen makes your skin activated.
5. Great safety: epidermis constant cooling, which could control the RF energy output and its speed. Therefore, make a better treatment results under the safe state.
6. Comfortable: non-invasive radio frequency technology, no blood, wound, or lay off.
7. Long effect: one treatment makes you feel the best result, and last for 3-5 years.
8. Treatment extensive: applied to anyone’s sagging skin and aging skin.
1. Pregnant women
2. Sensitive skin and allergic skin
3. Epileptic, scar skin and bad health
4. Wound around the treatment area
5. Metals inside of the body (without the loop-shaped intrauterine device)
6. Over expect on the result
1. Voltage: 220V/110V, 60Hz/50Hz.
2. RF frequency: 0-10 MHZ
3. RF energy: 0-50J/cm2
4. Output model: mono-polar, bipolar
5. Output control mode: Handle Switch,
7. Head: Pen-shape head (bi-polar)
8. Temperature of probe: -10 oC-0 oC
9. Screen: 10.4 inches real color touching screen
10. Output power: 900w
11. Size: 55 x 43x 115 cm
12. Weight: 50Kg
1. before operation:
A: To the device:
1. Make sure there are enough water into the device, and water circulation inside
When machine work 10 minutes to half hour at the first time, fill in more water, because there is some water go into the cycle system, the water in tank is short. Add more water can get a better cooling effect.
2. How to know it’s of enough water?
After good installation, screw offs the screw caps of water inlet and overflow at the same time. Then input the water through water tube and water pipe, automatic spilt water steam from the spillway, means enough water.
3. Water source: pure water or distilled water
Waiting some times before operation: when turn on the device; it should wait for some times to start the operation. Because the cooling system and water circulation must be in a good condition before the operation, so must wait for some times. Generally, do operation with big probe should wait for about 5 minutes; do operation with small probe, should wait for about 3 minutes.
B:To the patients:
1. Make sure no metals inside the body, such as the implanted electronic device etc.
2. Make sure no metals on surface of skin, such as watch or bracelet etc.
3. It is not allowed to treat on heart area .When do treatment on face, it’s better to paste the cathode polar patch on wrist.
4. Increase the energy little by little.
5. Before operation, make sure put cooling gel on treatment part, about 3mm thickness.
6. After treatment, use the makeup that including high water
C: Operation
1. Total two probes; different probe has different values in the treatment.
2. Value in the treatment:
A: small bi probe RF energy: generally start from 40, then adjust according to the actual condition of the patients
B: Need adjust the RF energy higher when use Bi-polar treatment than Mono-polar treatment.
C: the energy is started lower when use the small probe than the big probe.
3. Refrigeration: Please make sure that open the cooling in the treatment.
4. Operating step
Step one: Clean the skin, to eliminate the perfume and cosmetics on skin
Step two: Put some cooling gel on skin, about 3MM thickness
Step three: Vertically keep the probe closely on skin, and quickly move the probe back and forth alternately till feel heat, skin will feet hot after a few second. The treatment lasting time, face is about 15 minutes. body is about 40-60 minutes. When the skin become a little tumid, the treatment can be closed.
Step four: When finish treatment, please keep the cooling gel on skin for about half an hour, then scrub the cooling gel and wash skin with water.
Attention: please make sure the probe touch the skin, then make the machine on “work” status, when you finish the treatment, first stop the work machine, and then make the probe leave skin, if there is space between probe and skin when on ”work” status, it will burn the skin, because the machine is too high on frequency.
5. Treatment period:
One treatment every two weeks, 10 treatments is one treatment period.
please refer below info for the track on face or body